Path A · installed systems
Existing BMS & PLC
Read available operating values from the existing automation layer without changing its control sequence.

Unify building systems, IoT infrastructure and facility workflows through the AGAD cloud platform, with predictive insight and an AI assistant supporting faster, better informed decisions.
ONE VIEW
Portfolio-wide operational visibility
EARLY SIGNAL
Maintenance risks surfaced before disruption
CONNECTED
Existing systems unified through open integration
ACTIONABLE
KPIs, alarms and work orders aligned
Connected operations
Connected Buildings bring operational technology, IoT sensing and facility workflows into one accountable operating model. Instead of isolated BMS screens, meter portals and maintenance records, teams gain a consistent view from field equipment to portfolio performance.
NET WIZARDS combines smart building IoT, edge connectivity, industrial integration and the AGAD cloud platform to help facility management teams monitor conditions, identify risk and coordinate action across individual properties or multi-site communities in the UAE and GCC.

Operational context
People remain in control of every decision
AGAD cloud platform
AGAD connects edge IoT gateways and sensors with analytics and control tools. It gives facility teams a common operational layer for assets, alarms, performance indicators and service workflows—across one building or an entire portfolio.
Multi-site scalability with location and tenant data isolation.
Support for finding signals, interpreting context and guiding technical follow-up.
Operating patterns help teams identify abnormal conditions and maintenance priorities.
Relevant alarms, status and workflows stay accessible to teams in the field.

Building command centre
The command centre gives facility leaders a rapid portfolio view while preserving the asset-level detail engineers need. Teams can compare building health, alarms and maintenance exposure, then manage reusable PPM plans by asset type, frequency and assigned sites.
Illustrative interface · demonstration data

Building connectivity, critical alarms, open work orders and PPM exposure remain visible together.

Standardize maintenance by asset class, checklist depth, service frequency and building assignment.
AI-assisted diagnostics
A supervisor scans an asset QR code and asks AGAD to retrieve the Chiller-02 record. The assistant correlates temperature, pressure, differential pressure, electrical current and maintenance history before presenting a possible fault path for engineering review.
Illustrative scenario · synthetic readings · human verification required
Asset identity
Central plant · Building 01
Leaving water
9.8 °C
+2.1 °C vs baseline
Return water
14.7 °C
ΔT 4.9 °C
Discharge pressure
12.6 bar
Rising trend
Differential pressure
64 kPa
Declining trend
Motor current
118 A
+14% vs baseline
Run hours
3,842 h
Service context
AGAD Facility Assistant
Asset context connected
Samples
43,200
Alarms
3
Last PPM
18 days
Possible issue detected — engineering review recommended
Leaving-water temperature and discharge pressure are rising while differential pressure is declining. Motor current is also 14% above its recent baseline. Together, these signals may indicate reduced heat rejection or condenser-side fouling, rather than a single temperature sensor fault.
Recommended checks
Edge-to-cloud architecture
Existing PLC and BMS data is read through compatible protocol conversion, while an added sensor layer captures conditions not already available. Both streams are normalized at the edge and sent securely to AGAD for visibility, analysis and maintenance decisions.
Read-only monitoring layer
NET WIZARDS does not replace, bypass or take control of the installed BMS. Data moves outward for monitoring and decision support; the building’s existing control logic remains untouched.
Path A · installed systems
Read available operating values from the existing automation layer without changing its control sequence.
Path B · added sensing

Site-specific sensors can add temperature, humidity, pressure, differential pressure, current, vibration and leakage telemetry where required.
Edge integration

Protocol converters and the edge gateway collect, normalize and securely forward selected monitoring points.
Cloud destination
A unified monitoring layer for building and portfolio operations.
Operational applications
Select a capability to see how connected data supports day-to-day facility decisions.
Designed for every decision layer
See asset health, alarms, energy, service performance and maintenance priorities without switching between disconnected tools.
Compare sites through consistent KPIs, understand operational exposure and connect investment decisions to measurable building performance.
Integrate field protocols, gateways, networks, cloud services and CMMS workflows without discarding viable installed infrastructure.
Implementation path
A phased approach protects operational continuity while creating a scalable foundation for future sites and use cases.
Map assets, systems, protocols, operational priorities and reporting requirements.
Deploy or integrate sensors, meters, controllers, gateways and communication networks.
Model sites, users, KPIs, alarms, workflows and CMMS touchpoints in AGAD.
Validate data, operating logic, dashboards and stakeholder workflows before handover.
Use operational history, predictive signals and AI-assisted insight to improve performance.
Smart Community · Technical brief
Speak with our engineers about the systems, protocols and operational priorities in your portfolio.
Explore our Smart City solutions and Industrial Cloud platform.